Electrical Specifications
- Ingress protection:IP54
- C stake, P stake and Noise check Automatic
- Noise rejection:40 V pk to pk 2-wire, 3-wire, 4-wire test Yes, no shorting links required
- No disconnect testing (ART) Yes, with MCC CLAMP
- Stakeless measurement :Yes, with MCC CLAMP and MVC CLAMP
- Instrument output:Voltage: ±25 V or ±50 V at 94 Hz, 105 Hz, 111 Hz and 128 Hz
- Current: 4.5 mA or 0.45 mA or 0.045 mA
- Ground current range with clamp:0.5 mA to 19.9 A
- Ground current accuracy:5% ±3 digits
- Ground voltage range:0 to 100 V ac
- Ground voltage accuracy:2% ±2 V
- Resistance ranges:2, 3, 4 pole: 0.01 O to 200 kO
- ART: 0.01 O to 200 kO
- Stakeless: 0.01 O to 200 O
- Resistance accuracy
• 2P measurements: 2% ±3 digits
• 3P measurements: 2% ±3 digits
• 4P measurements: 2% ±3 digits
- ART measurements: 5% ±3 digits
- Stakeless measurements: 7% ±3 digits
- Maximum probe resistance
• Rp limit: 200 kO (50 V output voltage)
• Rc limit: 200 kO (50 V output voltage)
- Limits reduced to 100 kO for 25 V output voltage
- Limits reduced to 5 kO for 0.01 O resolution
- Display:31/2 digit high contrast liquid crystal, backlit
- Battery type: 8 off AA (LR6) NiMH rechargeable cells
- Safety Complies with the requirements of IEC61010-1 100V CAT IV between terminal pairs
- EMC In accordance with IEC61326-1
- Standards Compliance
- Complies with the requirements of KEMA K85B
- Complies with the following parts of EN61557, “Electrical safety in
- low voltage distribution systems up to 1000 V a.c. and 1500 V d.c.
- Equipment for testing, measuring or monitoring of protective measures
|
General Specifications
- Dimensions
- 203 mm x 148 mm x 78 mm (8 in x 5.8 in x 3 in)
- Weight:1kg (2.2lb)
- Operating temperature range -15 °C to +55 °C / 5 °F to 131 °F
- Storage temperature range-40 °C to +70 °C / -40 °F to 158 °F
|
Brand SKU
NA
|
Rashi Part SKU
NA
|
Warranty
1 Year
|