General Specifications
- Speed of Autotest DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds
- DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
- Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
- Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
- Display 5.7 in LCD display with a projected capacitance touchscreen
- Case High impact plastic with shock absorbing overmold
- Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
- Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
- Main unit and remote: Lithium ion battery pack, 7.2 V
- Typical battery life: 8 hours
- Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
- Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
- Calibration Service center calibration period is 1 year
|