Fluke Networks
Fluke -MS2-TTK - Copper Cable Testers and Tone Generators
Model No :
MS2-TTK
Part Code :
3052592

Overview

The MicroScanner2 Cable Verifier presents a revolutionary change in voice, data, and video cable testing. It starts by taking results from what was four different test modes and displaying them all at once – graphical wiremap, pair lengths, distance to fault, cable ID, and far end device.

Features
- Revolutionary Interface
- Multimedia Support
- IntelliTone Toning
- VDV Service Detection
- Rugged Housing

General Specifications
- Twisted-pair: UTP, FTP, SSTP 8-pin modular jack accepts 8-pin modular (RJ45) and 4-pin modular (RJ11) plugs; Coax: F-connector for 75 O, 50 O, 93 O cables
- Cable Tests
- Length (460 m or 1500 ft. with resolution to 0.3 m or 1 ft.), wiremap to TIA-568A/B standards, remote ID locators; displays results on one screen
- Tone Generator: IntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz]
- PoE Detection: Solicits and detects the presence of 802.3af compatible PoE (Power over Ethernet) devices
- Ethernet Port Test: Advertised speed of 802.3 Ethernet ports (10/100/1000)
- Power Source:
• Battery type: 2 AA (NEDA 15A, IEC LR6) alkaline batteries
• Battery life: 20 hours of typical use
• Other compatible battery types: 2 AA photo lithium, NIMH, NICAD
- Dimensions: 3 in x 6.4” x 1.4 in (7.6 cm x 16.3 cm x 3.6 cm)
- Weight: 0.8 lbs. (363 grams)
- Display: Monochrome liquid crystal display (LCD) with backlight
- Calibration: User-configurable NVP for twisted pair and coax; determines actual NVP with known length of cable
- Operating Temperature: 32 °F to 113 °F (0 oC to 45 oC)
- Storage Temperature: -4 °F to +140 °F (-20 oC to +60 oC)
- Operating Humidity: 90 % (50 °F to 95 °F; 10 oC to 35 oC) (%RH without condensing) (75 % (95 °F to 113 °F; 35 oC to 45 oC)
- Shock Vibration Meets requirements for MIL-PRF-28800F for Class 2 random vibration; 1 m drop test with and without wiremap adapter attached
- Safety EN 61010-1 2nd Edition
- Altitude 4000 m; Storage: 12000 m
- EMC EN 61326-1
- Agency Certifications N10140 C-Tick EMC standard; FCC Part 15 Class A; CE European Union Directives Pollution Degree 2